Review



three-chamber sociability test apparatus  (Stoelting inc)


Bioz Verified Symbol Stoelting inc is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Stoelting inc three-chamber sociability test apparatus
    Three Chamber Sociability Test Apparatus, supplied by Stoelting inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/bio_rxiv__2024__04__16__589760-53-5-9?v=Stoelting+inc
    Average 90 stars, based on 1 article reviews
    three-chamber sociability test apparatus - by Bioz Stars, 2026-08
    90/100 stars

    Images



    Similar Products

    86
    Muromachi Kikai x 40 cm2 sociability apparatus
    X 40 Cm2 Sociability Apparatus, supplied by Muromachi Kikai, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/10__1016_slash_j__isci__2026__115860-670-12-18?v=Muromachi+Kikai
    Average 86 stars, based on 1 article reviews
    x 40 cm2 sociability apparatus - by Bioz Stars, 2026-08
    86/100 stars
      Buy from Supplier

    93
    UGO Basile S.R.L interaction apparatus
    Interaction Apparatus, supplied by UGO Basile S.R.L, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/pm41045335-49-2-4?v=UGO+Basile+S.R.L
    Average 93 stars, based on 1 article reviews
    interaction apparatus - by Bioz Stars, 2026-08
    93/100 stars
      Buy from Supplier

    90
    Muromachi Kikai sociability apparatus sc-03m
    Three-chamber test. ( A ) Results of session 1, <t>sociability</t> test. ( B ) Results of session 2, social novelty preference. In small round wire cages in the left and right of three chambers, a 25 mm sponge cube (novel object) or a 14-week-old male C57BL/6J mouse with no prior contact with the test mouse was enclosed, respectively (session 1). The test mice were placed to the middle chamber and allowed to explore it for 10 min. To determine the interaction time, the total duration that the head of the test mouse was within the zone that was set at 30 mm around each of the cages was automatically counted using animal behavior analysis software. The interaction time for the novel object significantly decreased in the 6-OHDA group compared with the sham group, but there was no significant difference for the social object. After the session, the 14-week-old male C57BL/6J mouse was again placed in the holding cage (familiar), and a second unfamiliar mouse (stranger) was enclosed in the other wire cage on the opposite side (session 2). The rest of the procedure was conducted in the same way as mentioned above for session 1. The interaction time for either the familiar or stranger mouse did not significantly differ between the two groups. The data are expressed as the mean ± SEM with data point overlap. * p < 0.05.
    Sociability Apparatus Sc 03m, supplied by Muromachi Kikai, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/pmc11276653-239-7-10?v=Muromachi+Kikai
    Average 90 stars, based on 1 article reviews
    sociability apparatus sc-03m - by Bioz Stars, 2026-08
    90/100 stars
      Buy from Supplier

    90
    UGO Basile S.R.L sociability apparatus
    Three-chamber test. ( A ) Results of session 1, <t>sociability</t> test. ( B ) Results of session 2, social novelty preference. In small round wire cages in the left and right of three chambers, a 25 mm sponge cube (novel object) or a 14-week-old male C57BL/6J mouse with no prior contact with the test mouse was enclosed, respectively (session 1). The test mice were placed to the middle chamber and allowed to explore it for 10 min. To determine the interaction time, the total duration that the head of the test mouse was within the zone that was set at 30 mm around each of the cages was automatically counted using animal behavior analysis software. The interaction time for the novel object significantly decreased in the 6-OHDA group compared with the sham group, but there was no significant difference for the social object. After the session, the 14-week-old male C57BL/6J mouse was again placed in the holding cage (familiar), and a second unfamiliar mouse (stranger) was enclosed in the other wire cage on the opposite side (session 2). The rest of the procedure was conducted in the same way as mentioned above for session 1. The interaction time for either the familiar or stranger mouse did not significantly differ between the two groups. The data are expressed as the mean ± SEM with data point overlap. * p < 0.05.
    Sociability Apparatus, supplied by UGO Basile S.R.L, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/pmc11261032-277-48-48?v=UGO+Basile+S.R.L
    Average 90 stars, based on 1 article reviews
    sociability apparatus - by Bioz Stars, 2026-08
    90/100 stars
      Buy from Supplier

    90
    Stoelting inc three-chamber sociability test apparatus
    Three-chamber test. ( A ) Results of session 1, <t>sociability</t> test. ( B ) Results of session 2, social novelty preference. In small round wire cages in the left and right of three chambers, a 25 mm sponge cube (novel object) or a 14-week-old male C57BL/6J mouse with no prior contact with the test mouse was enclosed, respectively (session 1). The test mice were placed to the middle chamber and allowed to explore it for 10 min. To determine the interaction time, the total duration that the head of the test mouse was within the zone that was set at 30 mm around each of the cages was automatically counted using animal behavior analysis software. The interaction time for the novel object significantly decreased in the 6-OHDA group compared with the sham group, but there was no significant difference for the social object. After the session, the 14-week-old male C57BL/6J mouse was again placed in the holding cage (familiar), and a second unfamiliar mouse (stranger) was enclosed in the other wire cage on the opposite side (session 2). The rest of the procedure was conducted in the same way as mentioned above for session 1. The interaction time for either the familiar or stranger mouse did not significantly differ between the two groups. The data are expressed as the mean ± SEM with data point overlap. * p < 0.05.
    Three Chamber Sociability Test Apparatus, supplied by Stoelting inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/bio_rxiv__2024__04__16__589760-53-5-9?v=Stoelting+inc
    Average 90 stars, based on 1 article reviews
    three-chamber sociability test apparatus - by Bioz Stars, 2026-08
    90/100 stars
      Buy from Supplier

    93
    UGO Basile S.R.L rectangular apparatus
    Three-chamber test. ( A ) Results of session 1, <t>sociability</t> test. ( B ) Results of session 2, social novelty preference. In small round wire cages in the left and right of three chambers, a 25 mm sponge cube (novel object) or a 14-week-old male C57BL/6J mouse with no prior contact with the test mouse was enclosed, respectively (session 1). The test mice were placed to the middle chamber and allowed to explore it for 10 min. To determine the interaction time, the total duration that the head of the test mouse was within the zone that was set at 30 mm around each of the cages was automatically counted using animal behavior analysis software. The interaction time for the novel object significantly decreased in the 6-OHDA group compared with the sham group, but there was no significant difference for the social object. After the session, the 14-week-old male C57BL/6J mouse was again placed in the holding cage (familiar), and a second unfamiliar mouse (stranger) was enclosed in the other wire cage on the opposite side (session 2). The rest of the procedure was conducted in the same way as mentioned above for session 1. The interaction time for either the familiar or stranger mouse did not significantly differ between the two groups. The data are expressed as the mean ± SEM with data point overlap. * p < 0.05.
    Rectangular Apparatus, supplied by UGO Basile S.R.L, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/pmc10901619-153-6-30?v=UGO+Basile+S.R.L
    Average 93 stars, based on 1 article reviews
    rectangular apparatus - by Bioz Stars, 2026-08
    93/100 stars
      Buy from Supplier

    90
    Stoelting inc 3 chamber sociability apparatus
    Three-chamber test. ( A ) Results of session 1, <t>sociability</t> test. ( B ) Results of session 2, social novelty preference. In small round wire cages in the left and right of three chambers, a 25 mm sponge cube (novel object) or a 14-week-old male C57BL/6J mouse with no prior contact with the test mouse was enclosed, respectively (session 1). The test mice were placed to the middle chamber and allowed to explore it for 10 min. To determine the interaction time, the total duration that the head of the test mouse was within the zone that was set at 30 mm around each of the cages was automatically counted using animal behavior analysis software. The interaction time for the novel object significantly decreased in the 6-OHDA group compared with the sham group, but there was no significant difference for the social object. After the session, the 14-week-old male C57BL/6J mouse was again placed in the holding cage (familiar), and a second unfamiliar mouse (stranger) was enclosed in the other wire cage on the opposite side (session 2). The rest of the procedure was conducted in the same way as mentioned above for session 1. The interaction time for either the familiar or stranger mouse did not significantly differ between the two groups. The data are expressed as the mean ± SEM with data point overlap. * p < 0.05.
    3 Chamber Sociability Apparatus, supplied by Stoelting inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/bio_rxiv__2022__08__03__502603-393-6-9?v=Stoelting+inc
    Average 90 stars, based on 1 article reviews
    3 chamber sociability apparatus - by Bioz Stars, 2026-08
    90/100 stars
      Buy from Supplier

    93
    UGO Basile S.R.L apparatus
    Three-chamber test. ( A ) Results of session 1, <t>sociability</t> test. ( B ) Results of session 2, social novelty preference. In small round wire cages in the left and right of three chambers, a 25 mm sponge cube (novel object) or a 14-week-old male C57BL/6J mouse with no prior contact with the test mouse was enclosed, respectively (session 1). The test mice were placed to the middle chamber and allowed to explore it for 10 min. To determine the interaction time, the total duration that the head of the test mouse was within the zone that was set at 30 mm around each of the cages was automatically counted using animal behavior analysis software. The interaction time for the novel object significantly decreased in the 6-OHDA group compared with the sham group, but there was no significant difference for the social object. After the session, the 14-week-old male C57BL/6J mouse was again placed in the holding cage (familiar), and a second unfamiliar mouse (stranger) was enclosed in the other wire cage on the opposite side (session 2). The rest of the procedure was conducted in the same way as mentioned above for session 1. The interaction time for either the familiar or stranger mouse did not significantly differ between the two groups. The data are expressed as the mean ± SEM with data point overlap. * p < 0.05.
    Apparatus, supplied by UGO Basile S.R.L, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/sociability+apparatus/pm34847180-158-8-12?v=UGO+Basile+S.R.L
    Average 93 stars, based on 1 article reviews
    apparatus - by Bioz Stars, 2026-08
    93/100 stars
      Buy from Supplier

    Image Search Results


    Three-chamber test. ( A ) Results of session 1, sociability test. ( B ) Results of session 2, social novelty preference. In small round wire cages in the left and right of three chambers, a 25 mm sponge cube (novel object) or a 14-week-old male C57BL/6J mouse with no prior contact with the test mouse was enclosed, respectively (session 1). The test mice were placed to the middle chamber and allowed to explore it for 10 min. To determine the interaction time, the total duration that the head of the test mouse was within the zone that was set at 30 mm around each of the cages was automatically counted using animal behavior analysis software. The interaction time for the novel object significantly decreased in the 6-OHDA group compared with the sham group, but there was no significant difference for the social object. After the session, the 14-week-old male C57BL/6J mouse was again placed in the holding cage (familiar), and a second unfamiliar mouse (stranger) was enclosed in the other wire cage on the opposite side (session 2). The rest of the procedure was conducted in the same way as mentioned above for session 1. The interaction time for either the familiar or stranger mouse did not significantly differ between the two groups. The data are expressed as the mean ± SEM with data point overlap. * p < 0.05.

    Journal: International Journal of Molecular Sciences

    Article Title: Mouse Model of Parkinson’s Disease with Bilateral Dorsal Striatum Lesion with 6-Hydroxydopamine Exhibits Cognitive Apathy-like Behavior

    doi: 10.3390/ijms25147993

    Figure Lengend Snippet: Three-chamber test. ( A ) Results of session 1, sociability test. ( B ) Results of session 2, social novelty preference. In small round wire cages in the left and right of three chambers, a 25 mm sponge cube (novel object) or a 14-week-old male C57BL/6J mouse with no prior contact with the test mouse was enclosed, respectively (session 1). The test mice were placed to the middle chamber and allowed to explore it for 10 min. To determine the interaction time, the total duration that the head of the test mouse was within the zone that was set at 30 mm around each of the cages was automatically counted using animal behavior analysis software. The interaction time for the novel object significantly decreased in the 6-OHDA group compared with the sham group, but there was no significant difference for the social object. After the session, the 14-week-old male C57BL/6J mouse was again placed in the holding cage (familiar), and a second unfamiliar mouse (stranger) was enclosed in the other wire cage on the opposite side (session 2). The rest of the procedure was conducted in the same way as mentioned above for session 1. The interaction time for either the familiar or stranger mouse did not significantly differ between the two groups. The data are expressed as the mean ± SEM with data point overlap. * p < 0.05.

    Article Snippet: The three-chamber test was conducted using a sociability apparatus (SC-03M, Muromachi Kikai) to assess sociability and social novelty preference [ , ].

    Techniques: Software